Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
BMC Infect Dis ; 22(1): 145, 2022 Feb 10.
Artigo em Inglês | MEDLINE | ID: mdl-35144535

RESUMO

BACKGROUND: Because of the loss of chloroquine (CQ) effectiveness, the Democratic Republic of Congo (DRC)'s malaria treatment policy replaced CQ by sulfadoxine-pyrimethamine (SP) as first-line treatment of uncomplicated malaria in 2003, which in turn was replaced by artemisinin-based combination therapies (ACT) in 2005. The World Health Organization (WHO) recommends monitoring of anti-malarial drug resistance every 2 years. The study aimed to provide baseline data for biennial molecular surveillance of anti-malarial drug resistance by comparing data from a study conducted in 2019 to previously published data from a similar study conducted in 2017 in the DRC. METHODS: From July to November 2019, a cross-sectional study was conducted in ten sites which were previously selected for a similar study conducted in 2017 across the DRC. P. falciparum malaria was diagnosed by a rapid diagnostic test (RDT) or by microscopy and dried blood samples (DBS) were taken from patients who had a positive test. Segments of interest in pfcrt and pfk13 genes were amplified by conventional PCR before sequencing. RESULTS: Out of 1087 enrolled patients, 906 (83.3%) were PCR-confirmed for P. falciparum. Like in the 2017-study, none of the mutations known to be associated with Artemisinine (ART) resistance in Southeast Asia was detected. However, non-synonymous (NS) mutations with unknown functions were observed among which, A578S was detected in both 2017 and 2019-studies. The overall prevalence of pfcrt-K76T mutation that confers CQ-resistance was 22.7% in 2019-study compared to 28.5% in 2017-study (p-value = 0.069), but there was high variability between sites in the two studies. Like in 2017-study, the pfcrt 72-76 SVMNT haplotype associated with resistance to amodiaquine was not detected. CONCLUSION: The study reported, within 2 years, the non-presence of molecular markers currently known to be associated with resistance to ART and to AQ in P. falciparum isolated in the DRC. However, the presence of polymorphisms with as-yet unknown functions was observed, requiring further characterization. Moreover, an overall decrease in the prevalence of CQ-resistance marker was observed in the DRC, but this prevalence remained highly variable from region to region.


Assuntos
Antimaláricos , Malária Falciparum , Antimaláricos/farmacologia , Antimaláricos/uso terapêutico , Estudos Transversais , República Democrática do Congo/epidemiologia , Combinação de Medicamentos , Resistência a Medicamentos/genética , Humanos , Malária Falciparum/tratamento farmacológico , Malária Falciparum/epidemiologia , Plasmodium falciparum/genética , Proteínas de Protozoários/genética
2.
J Clin Virol ; 144: 104991, 2021 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-34626880

RESUMO

AIMS: The aim of this study was to evaluate the performance of the automated Elecsys® SARS-CoV-2 antigen assay compared to RT-PCR taken as the gold standard for SARS-CoV-2 detection. METHODS: 225 nasopharyngeal swabs were randomly collected among which 123 were tested positive and 102 negatives for SARS-CoV-2 based on RT-PCR. Antigen dosing were performed on a Cobas 8000 e801 analyzer. RESULTS: The antigen test diagnosed SARS-CoV-2 infection status with an overall sensitivity of 65,85% (95% CI 56,76-74,16%), a specificity of 100% (95% CI 96,49-100%) with a Cut-off value ≥ 1. When the cut-off value for the antigen assay was set to > 0,673 COI, the accuracy reached its highest level with a sensitivity of 74,8% (95% CI 66,2 - 82,2%) and a specificity of 97,1% (95% CI 91,6 - 99,4%). Imprecision was estimated in accordance with manufacturer's claims. CONCLUSIONS: We obtained an overall sensitivity of 65,85% (95% CI 56,76-74,16%) and a specificity of 100% (95% CI 96,49-100%), slightly higher than the results reported by the manufacturer. Yet, it remains relatively low comparatively to what is generally acceptable for these antigenic assays (a relative sensitivity of 80%). We also noticed that the accuracy could reach its highest level if the cut-off is set above 0,673 which is lower than established by the manufacturer. Thus, our results suggest that the Elecsys® SARS-CoV-2 Antigen assays, should be improved prior to be used in a SARS-Cov-2 screening strategy. However, if one antigenic assay could demonstrate acceptable performance, it might be centralized in clinical laboratories, keeping the RT-PCR in a second phase for confirmation.


Assuntos
COVID-19 , SARS-CoV-2 , Antígenos Virais , Teste Sorológico para COVID-19 , Humanos , Nasofaringe , Sensibilidade e Especificidade
3.
Malar J ; 20(1): 144, 2021 Mar 11.
Artigo em Inglês | MEDLINE | ID: mdl-33706773

RESUMO

BACKGROUND: The national policy for malaria treatment of the Democratic Republic of Congo recommends two first-line artemisinin-based combinations for the treatment of uncomplicated malaria: artesunate-amodiaquine and artemether-lumefantrine. This study investigated the presence of markers associated with resistance to the current first-line artemisinin-based combination therapy (ACT) in isolates of Plasmodium falciparum from treatment failure patients in the Democratic Republic of Congo. METHODS: From November 2018 to November 2019, dried blood spots were taken from patients returning to health centres for fever within 28 days after an initial malaria treatment in six sentinel sites of the National Malaria Control Programme across Democratic Republic of Congo. The new episode of malaria was first detected by a rapid diagnostic test and then confirmed by a real-time PCR assay to define treatment failure. Fragments of interest in pfk13 and pfcrt genes were amplified by conventional PCR before sequencing and the Pfmdr1 gene copy number was determined by a TaqMan real-time PCR assay. RESULTS: Out of 474 enrolled patients, 364 (76.8%) were confirmed positive by PCR for a new episode of P. falciparum malaria, thus considered as treatment failure. Of the 325 P. falciparum isolates obtained from 364 P. falciparum-positive patients and successfully sequenced in the pfk13-propeller gene, 7 (2.2%) isolates carried non-synonymous mutations, among which 3 have been previously reported (N498I, N554K and A557S) and 4 had not yet been reported (F506L, E507V, D516E and G538S). Of the 335 isolates successfully sequenced in the pfcrt gene, 139 (41.5%) harboured the K76T mutation known to be associated with chloroquine resistance. The SVMNT haplotype associated with resistance to amodiaquine was not found. None of the isolates carried an increased copy number of the pfmdr1 gene among the 322 P. falciparum isolates successfully analysed. CONCLUSION: No molecular markers currently known to be associated with resistance to the first-line ACT in use were detected in isolates of P. falciparum from treatment failure patients. Regular monitoring through in vivo drug efficacy and molecular studies must continue to ensure the effectiveness of malaria treatment in Democratic Republic of Congo.


Assuntos
Amodiaquina/farmacologia , Antimaláricos/farmacologia , Combinação Arteméter e Lumefantrina/farmacologia , Artemisininas/farmacologia , Resistência a Medicamentos/genética , Proteínas de Membrana Transportadoras/genética , Proteínas Associadas à Resistência a Múltiplos Medicamentos/genética , Plasmodium falciparum/genética , Proteínas de Protozoários/genética , Adolescente , Adulto , Idoso , Criança , Pré-Escolar , República Democrática do Congo , Combinação de Medicamentos , Feminino , Marcadores Genéticos/genética , Humanos , Lactente , Recém-Nascido , Masculino , Pessoa de Meia-Idade , Falha de Tratamento , Adulto Jovem
4.
Lancet Infect Dis ; 21(4): e82-e92, 2021 04.
Artigo em Inglês | MEDLINE | ID: mdl-33125913

RESUMO

The spread of Plasmodium falciparum isolates carrying mutations in the kelch13 (Pfkelch13) gene associated with artemisinin resistance (PfART-R) in southeast Asia threatens malaria control and elimination efforts. Emergence of PfART-R in Africa would result in a major public health problem. In this systematic review, we investigate the frequency and spatial distribution of Pfkelch13 mutants in Africa, including mutants linked to PfART-R in southeast Asia. Seven databases were searched (PubMed, Embase, Scopus, African Journal Online, African Index Medicus, Bioline, and Web of Science) for relevant articles about polymorphisms of the Pfkelch13 gene in Africa before January, 2019. Following PRISMA guidelines, 53 studies that sequenced the Pfkelch13 gene of 23 100 sample isolates in 41 sub-Saharan African countries were included. The Pfkelch13 sequence was highly polymorphic (292 alleles, including 255 in the Pfkelch13-propeller domain) but with mutations occurring at very low relative frequencies. Non-synonymous mutations were found in only 626 isolates (2·7%) from west, central, and east Africa. According to WHO, nine different mutations linked to PfART-R in southeast Asia (Phe446Ile, Cys469Tyr, Met476Ile, Arg515Lys, Ser522Cys, Pro553Leu, Val568Gly, Pro574Leu, and Ala675Val) were detected, mainly in east Africa. Several other Pfkelch13 mutations, such as those structurally similar to southeast Asia PfART-R mutations, were also identified, but their relevance for drug resistance is still unknown. This systematic review shows that Africa, thought to not have established PfART-R, reported resistance-related mutants in the past 5 years. Surveillance using PfART-R molecular markers can provide valuable decision-making information to sustain the effectiveness of artemisinin in Africa.


Assuntos
Artemisininas/farmacologia , Resistência a Medicamentos/genética , Malária Falciparum/tratamento farmacológico , Plasmodium falciparum/genética , Proteínas de Protozoários/genética , África/epidemiologia , Antimaláricos/farmacologia , Antimaláricos/uso terapêutico , Artemisininas/uso terapêutico , DNA de Protozoário/genética , DNA de Protozoário/isolamento & purificação , Genes de Protozoários/genética , Humanos , Malária Falciparum/epidemiologia , Malária Falciparum/parasitologia , Mutação , Plasmodium falciparum/efeitos dos fármacos , Plasmodium falciparum/isolamento & purificação , Polimorfismo de Nucleotídeo Único
6.
Malar J ; 19(1): 121, 2020 Mar 20.
Artigo em Inglês | MEDLINE | ID: mdl-32197607

RESUMO

BACKGROUND: The loss of chloroquine (CQ) effectiveness has led to its withdrawal from national policies as a first-line treatment for uncomplicated malaria in several endemic countries, such as the Democratic Republic of Congo (DRC). The K76T mutation on the pfcrt gene has been identified as a marker of CQ resistance and the SVMNT haplotype in codons 72-76 on the same gene has been associated with resistance to amodiaquine (AQ). In the DRC, the prevalence of K76T has decreased from 100% in 2000 to 63.9% in 2014. The purpose of this study was to determine the prevalence of K76T mutations in circulating strains of Plasmodium falciparum, 16 years after CQ withdrawal in the DRC and to investigate the presence of the SVMNT haplotype. METHODS: In 2017, ten geographical sites across the DRC were selected. Dried blood samples were collected from patients attending health centres. Malaria was first detected by a rapid diagnostic test (RDT) available on site (SD Bioline Malaria Ag Pf or CareStart Malaria Pf) or thick blood smear and then confirmed by a P. falciparum species-specific real-time PCR assay. A pfcrt gene segment containing a fragment that encodes amino acids at positions 72-76 was amplified by conventional PCR before sequencing. RESULTS: A total of 1070 patients were enrolled. Of the 806 PCR-confirmed P. falciparum positive samples, 764 were successfully sequenced. The K76T mutation was detected in 218 samples (28.5%; 95% CI 25.4%-31.9%), mainly (96%) with the CVIET haplotype. Prevalence of CQ resistance marker was unequally distributed across the country, ranging from 1.5% in Fungurume to 89.5% in Katana. The SVMNT haplotype, related to AQ resistance, was not detected. CONCLUSION: Overall, the frequency of the P. falciparum CQ resistance marker has decreased significantly and no resistance marker to AQ was detected in the DRC in 2017. However, the between regions variability of CQ resistance remains high in the country. Further studies are needed for continuous monitoring of the CQ resistance level for its prospective re-use in malaria management. The absence of the AQ resistance marker is in line with the use of this drug in the current DRC malaria treatment policy.


Assuntos
Amodiaquina/uso terapêutico , Antimaláricos/uso terapêutico , Cloroquina/uso terapêutico , Resistência a Medicamentos/genética , Malária Falciparum/tratamento farmacológico , Proteínas de Membrana Transportadoras/genética , Proteínas de Protozoários/genética , Adolescente , Adulto , Idoso , Criança , Pré-Escolar , República Democrática do Congo/epidemiologia , Teste em Amostras de Sangue Seco , Humanos , Lactente , Recém-Nascido , Malária Falciparum/epidemiologia , Programas de Rastreamento , Pessoa de Meia-Idade , Mutação , Plasmodium falciparum/genética , Polimorfismo Genético , Estudos Prospectivos , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...